Purpose |
ICU Bed for use in Intensive Care Unit, designed for patient comfort, easy transfer to/from Emergency/OT/Ward, and to support point-of-care procedures including radiology. |
Type of ICU Bed Actuator |
Mechanical (Handle Operated) |
Type of Mechanism for Angular Motion Control |
Super Smooth Crank Screw Mechanism |
Type of Mechanism for Height Control |
Super Smooth Crank Screw Mechanism |
Bed Top Perforated |
Yes |
Radio Translucent Top (X-Ray Translucent) |
Yes |
Type of Side Panel |
Collapsible |
Number of Side Panels |
1 |
Shape of Head & Foot Panel/Board |
D-type |
Type of Head & Foot Panel |
Detachable Type |
Number of Hooks on IV Rod |
2 |
Rectangular Telescopic Tube Box Housing for Tension Spring |
NA for Super Smooth Crank Screw Mechanism & Hydraulic Mechanism for Height |
Angle & Height Indicator at Foot and Head Side |
No |
X-Ray Film Holder Usage |
One Side |
Power of Motor (HP) |
N/A |
Patient Constraint Belt on Both Sides |
No |
Number of Castors with Braking System |
2 |
Safe Working Load Capacity (Kg) |
150 |
Mattress Provided |
Yes |
ICU Mattress X-Ray Translucent |
Yes |
High Resilient & Bio-Density Foam Mattress |
Yes |
Mattress Translucency for Portable X-Ray |
Yes |
Cube Cut Design of Mattress for Airflow |
Yes |
Material of ICU Bed Mattress |
PU Foam |
Therapeutic Weight Limit for Mattress (Kg) |
150 |
Power Supply |
N/A for Mechanically Operated |
Resettable Overcurrent Breaker |
N/A for Handle Operated |
Warranty |
1 Year (Option of comprehensive warranty available through bidding, which supersedes normal warranty in the catalogue) |
Conformity to Safety & Electromagnetic Compatibility Standards |
IEC-60601-1-2:2001 or IS-13450 |
Material for Frame of Bed |
MS (Mild Steel) |
Material for Side Railing / Side Safety Guard |
MS (Mild Steel) |
Material for Head & Foot Panel / Board |
ABS Plastic |
Material for Bed Top Section |
MS (Mild Steel) |
Material for Wheels |
MS (Mild Steel) |
Maximum Adjustable Back Rest Angle |
0-70 Degrees |
Maximum Adjustable Knee Rest Angle |
0-40 Degrees |
Maximum Trendelenburg Angle |
10 Degrees (± 2 degree tolerance) |
Maximum Reverse Trendelenburg Angle |
10 Degrees (± 2 degree tolerance) |
Mean Coil Diameter of Tension Spring (Counter Weight Mechanism) |
N/A for Super Smooth Crank Screw Mechanism & Hydraulic Mechanism for Height |
Spring Coil Diameter (Counter Weight Mechanism) |
N/A for Super Smooth Crank Screw Mechanism & Hydraulic Mechanism for Height |
Clearance Between Bed Base Frame and Floor Surface |
120 mm |
Length of Bed (with 2% Tolerance) |
2000-2100 mm |
Width of Bed (with 2% Tolerance) |
950-1000 mm |
Spares (ICU Bed Mainframe) |
Not Supplied |
Spares (Pair of Bed Ends, Detachable) |
Not Supplied |
Spares (Collapsible Side Rails) |
Not Supplied |
Spares (IV Rods) |
Not Supplied |
Spares (Mattress Similar to One Supplied with ICU Bed) |
Not Supplied |
Certifications for Product |
CE |
Electric Shock Protection Level |
Class-B/Class-1 (N/A for Handle Operated) |